Fire Alarm Separation Panel
- Fire Alarm Separation Panel
Fire Alarm Separation Panel
A master control panel that keeps zone and fault status separated and clearly identified across a larger, multi-panel fire alarm installation — showing exactly which panel and which zone an alarm or fault is coming from, instead of a single combined signal.
- One master panel can supervise up to 31 slave panels
- Sequential communication with automatic fault reporting per panel
- Displays alarm/fault by both panel number and zone number
- Per-zone alarm, fault and sound-circuit fault indicators
- Keeps separate panels' status distinct instead of merging signals
- UL FM Listed
Product Overview
The HST Fire Alarm Separation Panel works as a master control unit for larger fire alarm installations built from multiple slave panels — one master can supervise up to 31 slave panels across a site. Rather than merging every alarm into one combined signal, it keeps each slave panel's status distinct, communicating with them sequentially and flagging a fault immediately if any panel fails to respond.
Alarm and fault events are shown by both panel number and zone number on the master display, so staff know exactly which building, floor or panel an event is coming from — not just that "an alarm somewhere" has occurred. Individual indicators cover zone 1 alarm/fault, zone 2 alarm/fault, and sound circuit alarm and fault, giving a clear breakdown of exactly what's happening at each connected panel.
Where it's used
- Multi-building campuses and industrial sites
- High-rise buildings with per-floor panels
- Shopping malls with multiple tenant panels
- Any site running several independent fire alarm panels
Technical Specifications
| Network Capacity | |
|---|---|
| Slave Panels Supported | Up to 31 per master panel |
| Communication Mode | Sequential, panel-by-panel polling |
| Fault Detection | Reports if a slave panel fails to respond |
| Indication | |
| Event Identification | Shown by panel number + zone number |
| Zone Indicators | Zone 1 alarm/fault, Zone 2 alarm/fault (per connected panel) |
| Sound Circuit | Sound alarm & sound fault LED |
| Purpose | |
| Function | Keeps multi-panel status separated and clearly sourced |
| Brand | |
| Manufacturer | HST — Master/Slave Separation Panel |
This entry is built from HST's documented master/slave panel functionality — ask us to confirm the exact model number and datasheet for your project size.
Key Features
Keeps Panels Distinct
Shows which specific panel an event came from, instead of one merged signal.
Large Network Support
One master panel supervises up to 31 slave panels across a site.
Automatic Fault Detection
Flags a panel immediately if it stops responding during polling.
Panel + Zone Identification
Displays exactly which panel and zone triggered the event.
Sound Circuit Monitoring
Separate alarm/fault indication for the sound circuit itself.
Built for Large Sites
Suited to campuses, high-rises and multi-tenant buildings with many panels.
Product Documents
Download product information, installation guidance and configuration documentation for the HST Fire Alarm Separation Panel.
Product Data Sheet
Product overview, supported panel architecture, indication functions and key system information.
View / Download PDFQuick Start Guide
System arrangement, panel identification, communication checks and commissioning reference.
View / Download PDFUser Manual
Operating concept, indications, troubleshooting and safety reference for the panel.
View / Download PDFNeed a document that isn't listed? Contact our team for assistance.
Need this for a project?
Send us your BOQ or drawings — we'll quote the full system, not just the device.