Accessory Fault Isolator

KIDDE Model: KI-IB — Detector Base with Fault Isolator

Accessory Fault Isolator

A detector mounting base with a built-in line fault isolator for Class A circuits. If a short develops anywhere on the loop, the isolator on either side of the fault opens automatically — keeping the rest of the loop in service.

  • Built-in line fault isolator for Class A circuits
  • Isolates a short from the rest of the loop within 23 msec
  • Self-restoring — no manual reset once the fault clears
  • Fits North American and European electrical box standards
  • Requires a detector installed to operate
  • UL FM Listed
UL FM Listed
Request Price Trade & project pricing available
AuthorizedKidde Distributor
Class ACircuit Rated
BulkPricing Available
FitsNA & EU Boxes

Product Overview

The Kidde KI-IB is a detector mounting base with a built-in line fault isolator, used on Class A fire alarm circuits to stop a single wiring short from taking down an entire loop. A detector head must be installed in the base for the isolator to function — the base does not operate on its own.

When a short occurs, every isolator on the circuit opens within 23 milliseconds. The loop controller then closes isolators one at a time, 10 milliseconds apart, starting from the side nearest the controller, until it reaches the isolator next to the fault — which reopens immediately, sealing off just the faulty section while the rest of the loop keeps reporting normally. This base does not support the GSA-LED remote indicator.

Where it's used

  • Class A wired fire alarm loops
  • Sites requiring fault-tolerant detection circuits
  • Hospitals, hotels & high-occupancy buildings
  • Loops where a single short must not disable coverage

Technical Specifications

Isolator Function
Circuit TypeClass A fire alarm circuits
Fault Response TimeAll isolators open within 23 msec of a short
Reclose Interval10 msec per isolator, from controller side inward
RecoverySelf-restoring, no manual reset required
RequiresDetector head installed to operate
Wiring
Wire Sizes Accepted#18, #16, #14, #12 AWG (0.75–2.5 mm²)
Preferred Wire#16–#18 AWG for ease of installation
GSA-LED SupportNot supported on this base
Mounting
North American Boxes1-gang, 3½" or 4" octagon, 4" square (1½" deep)
European BoxesBESA and single-gang, 60.3mm fixing centers
Brand
ManufacturerKidde — Model KI-IB

4" variant with trim skirt (KI-IB4) also available. Ask us for the manufacturer datasheet.

Key Features

Fast Fault Isolation

Opens every isolator on the circuit within 23 milliseconds of a short.

Keeps the Loop Alive

Only the faulty section drops out — the rest of the circuit stays reporting.

Self-Restoring

No manual reset needed once the short is cleared — the loop recovers on its own.

Class A Compliant

Built specifically for Class A circuit wiring topology.

Wide Box Compatibility

Fits standard North American and European electrical box formats.

Flexible Wire Sizing

Accepts #18 AWG through #12 AWG wire for varied installation needs.

Product Documents

Download product information, installation guidance and technical documentation for the Kidde KI-IB Detector Base with Fault Isolator.

PDF

Product Data Sheet

Technical specifications, fault-isolation operation, wiring and mounting information.

View / Download PDF
PDF

Quick Start Guide

Mounting, Class A wiring, detector installation and commissioning reference.

View / Download PDF
PDF

User Manual

Detailed operation, fault isolation sequence, wiring, maintenance and troubleshooting.

View / Download PDF

Need a document that isn't listed? Ask us and we'll send it over.

Need this for a project?

Send us your BOQ or drawings — we'll quote the full system, not just the device.