Accessory Plastic Base
- Accessory Plastic Base
Accessory Plastic Base
The standard mounting base for Kidde Signature Series detectors. It connects the detector head to the signalling line circuit and gives you accessible, room-side wiring terminals for a clean, reliable install.
- Standard base for Kidde Signature Series detectors
- Connects detector to the signalling line circuit (SLC)
- Wiring terminals accessible from the room side after mounting
- Supports GSA-LED remote indicator connection
- Fits North American and European electrical box standards
Product Overview
The Kidde KI-SB is the standard plastic mounting base used with Kidde Signature Series detectors. It sits between the detector head and the building wiring, carrying the signalling line circuit connection and giving installers a stable, field-serviceable mounting point.
Wiring terminals stay accessible from the room side once the base is mounted, so technicians can wire, test and swap detector heads without disturbing the base itself. It also provides a connection point for the GSA-LED remote indicator where a visible alarm status is needed outside the detector's immediate location.
Where it's used
- New fire alarm detector installations
- Detector head replacements & upgrades
- Retrofits onto existing electrical boxes
- Sites standardizing on Kidde Signature Series
Technical Specifications
| Compatibility | |
|---|---|
| Designed For | Kidde Signature Series detectors |
| Connects To | Signalling Line Circuit (SLC) |
| Accessory Support | GSA-LED remote indicator |
| Mounting | |
| North American Boxes | 1-gang, 3½" or 4" octagon, 4" square (1½" deep) |
| European Boxes | BESA and single-gang, 60.3mm fixing centers |
| Installation | |
| Wiring Access | Room-side accessible terminals |
| Material | Fire-rated plastic housing |
| Brand | |
| Manufacturer | Kidde — Model KI-SB |
Related bases also available: KI-SB4 (4" with trim skirt), KI-RB (with relay), KI-IB (with fault isolator), KI-ABST/ABLT/ABDT (audible/sounder bases). Ask us for the right variant.
Key Features
Reliable SLC Connection
Carries the signalling line circuit between the detector and the panel.
Room-Side Wiring Access
Terminals stay reachable after mounting — no need to pull the base off to work.
Field-Serviceable
Swap or replace the detector head without disturbing the base or its wiring.
GSA-LED Compatible
Supports connection to a remote LED indicator for visible alarm status.
Wide Box Compatibility
Fits standard North American and European electrical box formats.
Signature Series Fit
Purpose-built to pair with Kidde's Signature Series detector heads.